Refine your search
Co-Authors
Journals
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z All
Sahoo, K. C.
- On the Occurrence of Sargur Type Banded Iron-Formation in Banded Gneissic Complex of South Rajasthan
Abstract Views :225 |
PDF Views:1
Authors
K. C. Sahoo
1,
A. K. Mathur
1
Affiliations
1 Geological Survey of India, Jhalana Dungri, Jaipur, IN
1 Geological Survey of India, Jhalana Dungri, Jaipur, IN
Source
Journal of Geological Society of India (Online archive from Vol 1 to Vol 78), Vol 38, No 3 (1991), Pagination: 299-302Abstract
The occurrence of BIF from a part of Banded Gneissic Complex of Rajasthan is reported. Older than 3.0 Ga granites, their field-setting and petrochemical characters are comparable to the BIF of older supracrustals of south India (Sargur Group).Keywords
Banded Iron-Formation, Banded Gneissic Complex, Rajasthan.- Event Stratigraphy and Physico-Chemical Characters of Banded Gneissic Complex and Associated Supracrustals in the South Mewar Plains of Rajasthan
Abstract Views :173 |
PDF Views:1
Authors
Utpal Bose
1,
A. K. Mathur
1,
K. C. Sahoo
2,
S. Bhattacharya
1,
Krishan Dutt
1,
V. Aneel Kumar
3,
S. S. Sarkar
1,
S. Chowdhury
1,
I. Chowdhury
1
Affiliations
1 Geological Survey of India, Jhalana Dungri, Jaipur - 302 004, IN
2 Geological Survey of India, Bhubaneswar - 751 012, IN
3 Geological Survey of India, Hyderabad - 500 660, IN
1 Geological Survey of India, Jhalana Dungri, Jaipur - 302 004, IN
2 Geological Survey of India, Bhubaneswar - 751 012, IN
3 Geological Survey of India, Hyderabad - 500 660, IN
Source
Journal of Geological Society of India (Online archive from Vol 1 to Vol 78), Vol 47, No 3 (1996), Pagination: 325-338Abstract
The oldest cratonic nucleus pf the Western Indian shield, familiarly known as the Banded Gneissic Complex (BGC), occupies a large tract in the Mcwar plains of South Rajasthan. It has essentially an old gneissic component (3.3 Ga) and a host of mafic bodies associated with detrital and chemogenic sediments which have been subjected to multiple phases of anatexis and granite intrusions (2.9 Ga and later events). The emplacement of Berach granite and succeeding dolerite dyke swarms mark the end-Archaean cratonization process. This also initiated intracratonic and cratonmarginal basin formation.Later magmatism, especially along the basement-cover interface. is due to local remobilisation of the basement at the time of Proterozoic orogeny.
Keywords
Banded Gneissic Complex, Stratigraphy, Petrochemistry, Rajasthan.- Meteoritic Shower in Orlssa
Abstract Views :192 |
PDF Views:122
Authors
M. Mohanty
1,
K. C. Sahoo
1
Affiliations
1 Geological Survey of India Operation Orissa Nayapalli , Unit-8 Bhubaneswar - 751 012, IN
1 Geological Survey of India Operation Orissa Nayapalli , Unit-8 Bhubaneswar - 751 012, IN
Source
Journal of Geological Society of India (Online archive from Vol 1 to Vol 78), Vol 63, No 2 (2004), Pagination: 231-231Abstract
No Abstract.- National Seminar on Orissa's Mineral, Environment and Geosciences Assessment - 2011 (OMEGA-2011) and Golden Jubilee of Geological Survey of India, Orissa
Abstract Views :208 |
PDF Views:137
Authors
Source
Journal of Geological Society of India (Online archive from Vol 1 to Vol 78), Vol 78, No 4 (2011), Pagination: 390-390Abstract
No Abstract.- Effects Analysis of Incorporating Suction Line Heat Exchanger (SLHX) Combined with Adiabatic Capillary Tube in Vapor Compression Refrigeration (VCR) System Using R-600a
Abstract Views :362 |
PDF Views:7
Authors
Affiliations
1 Mechanical Department, Bhubaneswar Engineering College, Bhubaneswar, Odisha, IN
1 Mechanical Department, Bhubaneswar Engineering College, Bhubaneswar, Odisha, IN
Source
Technology Spectrum Review, Vol 2, No 2 (2017), Pagination: 1-6Abstract
This article experimentally analyses the effects of the incorporated Suction Line Heat Exchanger (SLHX) on the performance of vapor compression refrigerators to validate the theoretical relations. The set up uses concentric coiled SLHX combined with adiabatic Capillary tube. The model is based on mass, momentum and energy conservation equations on finite element procedure using R-600a as working fluid. This paper emphasizes on the target design of Domestic refrigerators incorporating such heat exchangers of any refrigeration capacity considering the effect of various geometric and operating parameters on performance of VCR. Here the eco-friendly refrigerant R-600a has additional advantage of low operating pressure range of 0.7 bar to 6 bar claiming for a small size compressor. In the present work the effect of incorporated SLHX on COP has been analyzed theoretically and experimentally and fond to increase by 7% and 3% respectively.Keywords
Adiabatic Capillary Tube, COP, Fanno Line, Heat Load.References
- D. A. Wolf, R. R. Bittle, and M. B. Pate, “Adiabatic capillary tube performance with alternative refrigerants: Final report,” ASHRAE-RP-762, 1995.
- K. C. Sahoo, and S. N. Das, “Phase change pressure drop in capillary of a domestic refrigerator,” IOSR Journal of Mechanical and Civil Engineering, vol. 11, no. 1 ver. III, pp. 79-85, Jan. 2014.
- R. R. Bittle, D. A. Wolf, and M. B. Pate, “A generalized performance prediction method for adiabatic capillary tubes,” HVAC & Research, vol. 14, no. 1, pp. 27-43, 1998.
- ASHRAE, ASHRAE Handbook Refrigeration, Ch. 44, Amer. Soc. Heat. Refrig. Air-cond. Engin., Atlanta, GA, USA., 1994.
- C. Melo, R. T. S. Ferreiraa, C. B. Netoa, J. M.Goncalvesa, and M. M. Mezavilaa, “An experimental analysis of adiabatic capillary tubes,” Applied Thermal Engineering, vol. 19, no. 6, pp. 669-684, 1999.
- S. M. Sami, and H. Maltais, “Experimental analysis of capillary tubes behavior with some R-22 alternative refrigerants,” International Journal of Energy Research, 2000.
- N. E. Hopkins, “Rating the restrictor tube,” Refrigerating Engineering, vol. 58, no. 11, pp. 1087-1095, 1950.
- H. A. Whitesel, “Capillary two-phase flow,” Refrigerating Engineering, p. 42, April 1957.
- ASHRAE Handbook, Equipment Volume, Section II, Refrigeration Equipment, Ch. 20, pp. 1-28, American Society of Heating, Refrigerating, and Air Conditioning Engineers, 1979.
- ASHRAE Refrigeration Handbook, Ch. 45, American Society of Heating, Refrigerating, and Air Conditioning Engineers, 1998.
- E. P. Mikol, “Adiabatic single and two-phase flow in small bore tubes,” ASHRAE Journal, vol. 5, no. 11, pp. 75-86, 1963.
- T. A. Hussain, “A numerical analysis of adiabatic capillary tube performance in vapor compression refrigeration system,” The Iraqi Journal for Mechanical and Material Engineering, vol. 8, no. 3, 2008.
- M. Ramgopal, “NPTEL tutorial on refrigeration & air conditioning,” lesson 24, IIT Kharagpur.
- C. P. Arora, “Expansion devices,” Refrigeration and Air Conditioning, Ch. 8, New Delhi, Mc Graw-Hill.
- R. C. Arora, “Expansion valves,” Refrigeration and Air Conditioning, Ch. 9, PHI, Delhi.
- C. Z. Wei, Y. T. Lin, C. C. Wang, and J. S. Lev, “An experimental study of the performance of capillary tubes for R-407C refrigerant,” ASHRAE Trans., vol. 27, 2001.